Our products
The wastewater treatment plants, produced in Lithuania (Small wastewater treatment systems for up to 50 PT – Part 3: Packaged and / or site assembled domestic wastewater treatment plants) are of high quality, satisfy the standard EN12566-3:2006+A1:2009 and are marked with the CE mark.
| Performance characteristic | Declared value or class | Name of laboratory / body and testing number |
|---|---|---|
| Effectiveness of treatment |
BOD5* – 97,2% CDScr* – 88,1% SS – 94,0% NH4 – 96,7% Ntotal- 61,7% Ptotal – 47,4% |
Prufberichts – Nr.PIA 2007-006 1) |
| Treatment capacity (nominal size) | Conformed | Daily hidraulic load, May 2007 2) |
| Watertightness | suitable | Testing protokol No.60-07-0499 3) |
| Crushing resistance | suitable | Testing protokol No.60-07-0099 3) |
| Material | polypropylene |
Name and adrresses of testing laboratories / bodies :
1. Prüfinstitut für Abwassertechnik GmbH, NB 1739Hergenrather Weg 30, 52074 Aachen, Germany



In summer 2008 Certification Centre of Building Products (SPSC) gave to factory a national certificate NTL-01-050:2008 for the wastewater treatment plants over 50 PT. This national certificate is compulsory for each company that wants to produce typical wastewater treatment plants to the market.
Domestic wastewater is liquid wastes generating during human domestic activity. It includes wastewater from bathroom, water closet, sink, washing and dish washing machines.
VFL technology wastewater treatment plants treat wastewater contaminated with organic and chemical pollutants (these are various detergents, washing means and other household products).
.
Biological wastewater treatment plant T6 – AT50
Small treatment plants AT6-50 , up to 50 GE treat the volume of sewage wastes at a rate of 0.5 up to 7.5 cub.m per day, when the wastewater is received from:
- A single house,
- Apartment houses, apartments,
- Hotels and boarding houses,
- Restaurants,
- Schools,
- Camping sites,
- Small-scale companies, etc.
| Type | AT6 | AT8 | AT10 | AT12 | AT15 | AT20 | AT30 | AT40 | AT50 |
|---|---|---|---|---|---|---|---|---|---|
| PT | 4 | 6 | 8 | 10 | 12 | 18 | 25 | 35 | 50 |
| Capacity (m3/d.) | 0.54 | 0.81 | 1.2 | 1.35 | 1.8 | 2.7 | 3.75 | 5.25 | 7.5 |
| Diameter of the plant(mm) | 1400 | 1400 | 1750 | 1750 | 2050 | 2050 | 2300 | 2850 | 2950 |
| Height of the plant(mm) | 1800 | 2200 | 2000 | 2200 | 2200 | 2700 | 3000 | 2700 | 3000 |
| Height of the inlet pipe (mm) | 1300 | 1700 | 1500 | 1700 | 1700 | 2200 | 2500 | 2200 | 2800 |
| Height of the outlet pipe (mm) | 1150 | 1500 | 1250 | 1500 | 1500 | 2000 | 2300 | 2000 | 2600 |
| Average electric consumption(kW/annum) | 208 | 270 | 411 | 582 | 782 | 1564 | 2689 | 2359 | 4254 |
| The excess sludge removal (m3/annum) | 1 | 1.5 | 2 | 2.5 | 3 | 4.5 | 6.3 | 8.8 | 12.5 |
Advantages of our patented wastewater treatment plants:
- High-performance, removes nitrogen and phosphorus;
- employs no chemical substances;
- diffuses no offensive odour;
- insensitive to peak flows;
- low power consumption (4PE uses 208 kWh/per annum);
- low generation of excess sludge (1 cub. m./per annum of excess sludge 4PE)
- occupies less space and spoils no aesthetic scenery, thus allows making the most of the available space;
- easy-to-use, cost-effective assembling and can be easily conveyed;
- can be left free of wastewater for 30 and more days, thus causing no problems in planning long-term trips and holidays;
- can operate under any weather conditions – due to the biological processes running in the plant, the contents of the tankages remains non-freezing even under a very low temperature;
- conforms to the highest ecological standards and produces no impact on the nature.
Moreover,
- These plant can be assembled and launched within 1 working day.
- Wastewater treatment parameters are available as of the moment the plant is started.
- The water treated in this wastewater treatment plant can be reused as service water.
At the present time only this producer in the Baltic States, holding the document issued by an independent laboratory, which guarantees that biological wastewater treatment plants are notable for high parameters of the treated wastewater.
Biological wastewater treatment plant T75 – AT250
AT biological reactors (hereinafter – bioreactors) are on-site aerobic continuous-flow wastewater treatment plants factory produced from extrusive polypropylene with active sludge for biological removal of organic pollutants (BDS and ChDS), nitrogen and phosphorus from household and industrial wastewater, which chemical compositions are similar.
| Type | Averagedaily flow(m3/d) | Averagedaily load(KG BDS5) | Dimensions of the biological reaktorDiameter X Height(mm) | Number of reactors | Sludge production(m3/annum) | Average el.energy consumptionkWH/d |
|---|---|---|---|---|---|---|
| AT75 | 11.3 | 3.60 | 3300X3000 | 1 | 18.8 | 12.0 |
| AT100 | 15.0 | 6.00 | 3500X3000 | 1 | 25.0 | 16.0 |
| AT120 | 18.0 | 7.20 | 4000X3000 | 1 | 30.0 | 20.0 |
| AT150 | 22.5 | 9.00 | 4500X3000 | 1 | 37.5 | 24.0 |
| AT200 | 30.0 | 12.0 | 5000X3000 | 1 | 50.0 | 33.0 |
| AT250 | 37.5 | 15.00 | 5300X3000 | 1 | 62.5 | 40.0 |
A bioreactor consists of anaerobic – anoxic, aeration zone and secondary sedimentation tank.
All zones are installed in a single horizontal repository of cylindrical shape and are separated by walls. By means of the airblower the excess sludge is removed into sludge stabilizer, which is mounted in a separate repository.
The treatment unit includes an air blower mounted next to the plant.
The shape, configuration, arrangement of treatment stages and equipment of bioreactors installed are analogous to all AT75 – AT250 models. Along with the increase in the capacity of bioreactors, the corresponding structural parameters of the equipment are increased.
—————————————————————————————————————————————————-
Municipal VFL wastewater treatment plant T300 – AT5000
Municipal VFL wastewater treatment plant AT300 – AT5000 is capable of servicing cities, towns with a large and small number of citizens: from several hundreds up to over five thousand citizens. Our project covers all levels of biological treatment and sludge sedimentation in the integrated reactor. It reduces the dimensions of the plant and simplifies construction works. The tankages of AT1000 – AT5000 bioreactors must be produced from reinforced concrete, whereas partitions can be installed from polypropylene.
| Type | V Averagedaily flow(m3/d) | Averagedaily load(KG BDS5) | Dimension of the biological reactorDiameter X Height(mm) | Number of reactors | Sludge production(m3/annum) | Average el.energy consumptionkWH/d |
|---|---|---|---|---|---|---|
| AT300 | 45.0 | 18.0 | 4500X3000 | 2 | 75.0 | 48.0 |
| AT400 | 60.0 | 24.0 | 5000X3000 | 2 | 100.0 | 66.0 |
| AT500 | 75.0 | 30.0 | 5300X3000 | 2 | 125.0 | 80.0 |
| AT600 | 90.0 | 36.0 | 5000X3000 | 3 | 150.0 | 99.0 |
| AT750 | 112.5 | 45.0 | 5300X3000 | 3 | 187.5 | 120.0 |
VFL technology bioreactor contains integrated all levels of biological treatment and sludge sedimentation (anaerobic – anoxic, aeration zone and secondary sedimentation tank). All zones are installed in the aerotanks of rectangular shape, which base is made from concrete and partitions – from polypropylene.
LAs compared to the traditional treatment methods, VFL technology is superior to both space and energy efficiency. Treatment system is flexible as the duration of all treatment stages can be easily changed and adjusted. The treatment plants of this type are fitted for treatment of unequal and varying wastewater debits and loads.
| Type | Average daily flow(m3/d) | Average daily load(KG BDS5) | Dimensions of the biological reactorlenght X width X height(m) | Number of reactors | Sludge productionKG/D | Average el.energy consumptionkWH/d |
|---|---|---|---|---|---|---|
| AT1000 | 150.0 | 60.0 | 11X9X3.5 | 2 | 30.0 | 144.0 |
| AT1500 | 225.0 | 90.0 | 12X9X4.0 | 2 | 45.0 | 195.0 |
| AT2000 | 300.0 | 120.0 | 13X10X4,0 | 2 | 60.0 | 260.0 |
| AT2500 | 375.0 | 150.0 | 12X12X4.5 | 3 | 75.0 | 300 |
| AT3000 | 450.0 | 180.0 | 13X13X4.5 | 3 | 90.0 | 360.0 |
| AT3500 | 525.0 | 210.0 | 14X13X4.5 | 3 | 105.0 | 421.0 |
| AT4000 | 600.0 | 240.0 | 18X12X4.5 | 4 | 120.0 | 481.0 |
| AT4500 | 675.0 | 270.0 | 18X13X4.5 | 4 | 135.0 | 534.0 |
| AT5000 | 750.0 | 300.0 | 20X13X4.5 | 4 | 150.0 | 587.0 |
| Parameter | Guaranteedvalue | Averagevalue | Parameter | Guaranteedvalue | Averagevalue | |
|---|---|---|---|---|---|---|
| ChDScr | 75 mg/l | 35 mg/l | ChDScr | 50 mg/l | 35 mg/l | |
| BDS5 | 15 mg/l | 10 mg/l | BDS5 | 7 mg/l | 5 mg/l | |
| SS | 25 mg/l | 15 mg/l | SS | 10 mg/l | 3 mg/l | |
| N-NH4 | 2 mg/l | 1 mg/l | N-NH4 | 2 mg/l | 1 mg/l | |
| Ntotal | 30 mg/l | 15 mg/l | Ntotal | 20 mg/l | 15 mg/l | |
| Ptotal | 6 mg/l | 3 mg/l | Ptotal | 5 mg/l | 3 mg/l | |
| Ptotal* | 2 mg/l | 1 mg/l | Ptot* | 2 mg/l | 1 mg/l | |
| Fecal coliforms | 20 / 100ml | 2 / 100 ml |